SIMULFL HSV, KIT-5ML

Code: 3293SIG D2-231

Components

SimulFluor® HSV1/2 Reagent - (Catalog No. 5243). One 5 mL dropper vial containing two components specific for HSV-1 and HSV-2, protein stabilizer, ...


read more

Your Price
€705.90 EACH
Discontinued
€868.26 inc. VAT

Sustainable Product Manufacturing

Components

SimulFluor® HSV1/2 Reagent - (Catalog No. 5243). One 5 mL dropper vial containing two components specific for HSV-1 and HSV-2, protein stabilizer, Evans blue and 0.1% sodium azide (preservative).HSV Control Slides - (Catalog No. 5093). Two slides containing one well of HSV-1 infected cells, one well of HSV-2 infected cells and one well of uninfected cells.Phosphate-Buffered Saline (PBS) - (Catalog No. 5087). One packet of phosphate-buffered saline salts.Tween 20/Sodium Azide Solution (100X) - (Catalog No. 5037). One 10 mL vial containing Tween 20 /sodium azide concentrate.Mounting Fluid - (Catalog No. 5013). One 10 mL dropper vial containing Tris-buffered glycerin, a fluorescence enhancer and 0.1% sodium azide (preservative).

Disclaimer

For in vitro Diagnostic UseCE Mark

General description

Diagnostics Kit

Legal Information

CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany

SimulFluor is a registered trademark of Merck KGaA, Darmstadt, Germany

Storage and Stability

When stored at 2-8°C, the Light Diagnostics SimulFluor® HSV 1/2 Immunofluorescence Assay kit is stable up to the expiration date printed on the kit label. Do not freeze or expose to elevated temperatures. Discard any remaining reagents after the kit expiration date.

Warnings and Precautions:

⋅ For in vitro diagnostic use

⋅ The sodium azide (NaN3) used as a preservative in the SimulFluor™ HSV 1/2 Reagent, PBS/Tween and Mounting Fluid is toxic if ingested. Sodium azide may react with lead and copper plumbing to form highly explosive metal azides (14, 15). Upon disposal, flush with large volumes of water to prevent build-up in plumbing.

⋅ Pooling or alteration of any reagent may cause erroneous results.

⋅ Do not substitute reagents from other manufacturers.

⋅ Incubation times or temperatures other than those specified may give erroneous results.

⋅ Do not allow shell vials or slides to dry at any time during the staining procedure.

⋅ Handle all specimens and materials coming in contact with them as potentially infectious and dispose of with proper precautions. Decontaminate with 0.05% sodium hypochlorite.

⋅ Acetone is extremely flammable and harmful if swallowed or inhaled. Keep away from heat, sparks or flame. Avoid breathing vapor. Use adequate ventilation.

⋅ Do not mouth pipette reagents.

⋅ Avoid contact with Evans blue (present in Reagent) as it is a potential carcinogen. If skin contact occurs, flush with large volumes of water.

⋅ Mounting Fluid contains a fluorescence enhancer that may be destructive to mucous membranes. Avoid direct skin or mucous membrane contact. If contact occurs, flush with large volumes of water.

biological sourcemouse
clonemonoclonal
conjugateSimulFluor®
detection methodfluorometric
manufacturer/tradenameChemicon®, Light Diagnostics, SimulFluor®
Quality Level600
shipped inwet ice
technique(s)immunofluorescence: suitable
This product has met the following criteria to qualify for the following awards:


Sustainable Product Manufacturing
  • Made in a facility which runs on >90% renewable energy

To find out more about our Sustainability Attributes, click here.

PROCEED TO CHECKOUT

HAVE AN ACCOUNT? LOGIN


GUEST CHECKOUT

Proceed as a guest. You will have the option to register to access exclusive pricing and stock availability features after checkout.